02840
PRIMARY RATE TRANSFORMER
A
Low Profile Mains Transformer designed for 120 or 240 Volt input (series or
parallel primaries) to give 8V + 8V output at 4VA

|
Inductance |
1.2
- 2.0 mH |
|
Leakage inductance |
0.5
µH max |
|
DC Resistance each
winding |
1.0
Ohm max |
lnterwinding
capacitance
3 - 4 to 1 - 2 + 5-6 |
25
pF max |
|
Isolation test
between windings |
500V
DC |
|
Ratio
3 - 4 : 1 - 2 : 5 - 6 |
1 : 1 : 1 |
Information
for guidance only
Specification subject to change
© OSEC
2000 Ltd.
|